title: "How to Specify Tubing: A Specification Template with Examples"
canonical: "https://yuannaitube.com/how-to-specify-tubing/"
language: "en-US"
---

RESOURCES

# How to Specify Tubing: A Specification Template with Examples

By  [YUANNAI TUBE](<https://yuannaitube.com/about/>) Published 2026-10-26Updated 2026-11-05

![Three tube samples in a steel block with a caliper and a drawing sheet](<https://yuannaitube.com/wp-content/uploads/2026/10/how-to-specify-tubing-cover-20261025-1024x683.webp>)

A tubing specification works when a supplier can quote it without a follow-up question. Write the product family and model, the ID × OD with tolerance, the length per roll and total quantity, the medium, the **working pressure** with its temperature, the color and marking, and the documents you need. This guide gives a copy-and-fill template and a worked example using real model rows.

**Quick answer.** One line per item, always with units: *family and model · ID × OD (mm) · tolerance · roll length and quantity · medium · **working pressure** at a stated temperature · color and marking · documents*. Naming the model code is what turns a size into a specification.

## The specification block

Use this block in an **inquiry**, a purchase order or a drawing note. The example column is a real model from the  [PA6 model table](<https://yuannaitube.com/products/pa6-nylon-tubing/>) .

| Line | What to write | Example |
| --- | --- | --- |
| Family and model | Material family and the model code | PA6 nylon tubing, YN-PA6 0640 |
| Size | ID × OD in the order shown, with units | 4.0 × 6.0 mm |
| Tolerance | Tolerance as listed for the model | ±0.10 mm |
| Length and quantity | Length per roll and total quantity | 200 m rolls, 2,000 m total |
| Medium | What flows through the tube, including oil or additives | Dry compressed air |
| Working pressure | Pressure with unit and the temperature it applies at | 35 bar (512 psi) at 23°C |
| Temperature range | Lowest and highest ambient and medium temperature | −10°C to +60°C |
| Routing | Fixed or moving, tightest bend | Fixed, 80 mm bend (model minimum 35 mm) |
| Hardness (only if required) | Scale, value or range, and test standard | Shore A, range from the fitting maker’s chart, ASTM D2240 |
| Color and marking | Color name and any marking or length print | Blue, standard marking |
| Packaging and delivery | Reel or coil, destination, target date | Standard roll packing, port of destination, target date |
| Documents | Data sheet, test reports or certificates required | Technical data sheet |

The pressure, temperature and bend values in the example are inputs from the buyer; only the model, size, tolerance, roll length and 35 bar **working pressure** come from the table. Replace them with your own line conditions.

## One size, three specifications

An 8 mm OD tube with a 6 mm ID exists in several materials, and the numbers differ. These three rows come straight from the model tables, all at 23°C:

| Model | Material | Size (mm) | Working pressure | Burst pressure | Bend radius (mm) |
| --- | --- | --- | --- | --- | --- |
| [YN-PU 0860](<https://yuannaitube.com/products/pu-tubing/>) | PU | 6.0 × 8.0 | 5 bar (75 psi) | 15 bar (227 psi) | 25 |
| [YN-PUR 0860](<https://yuannaitube.com/products/polyether-tubing/>) | Polyether PU | 6.0 × 8.0 | 8 bar (116 psi) | 24 bar (348 psi) | 40 |
| [YN-FEP 0860](<https://yuannaitube.com/products/fep-tubing/>) | FEP | 6.0 × 8.0 | 13 bar (182 psi) | 40 bar (580 psi) | 70 |

The same size fits the same push-in fitting, yet the **working pressure** ranges from 5 to 13 bar and the **bend radius** from 25 to 70 mm. A line that says only “6 × 8 tube” leaves all three open; a line that names the model closes it.

## Write it this way

- Write the **model code** and the material family, not just the tube type.

- Write **ID × OD** with units; add the tolerance shown in the model row.

- Write pressure with its **unit and temperature**, such as 35 bar at 23°C.

- Write **working pressure** as the operating value and keep burst pressure as a separate figure.

- Write the **color and marking** by name.

- Write the **roll length and total quantity**.

- List the **documents** you need with the order.

- Write **hardness** only when a fitting or application requires it: the scale (for example Shore A), the value or range, and the test standard. Do not convert between Shore scales; see  [tubing Shore hardness](<https://yuannaitube.com/tubing-shore-hardness/>)  for the values on our data sheets.

## Where to find each value

- Model code, size, tolerance, pressures and **bend radius**: the model table on each product page, or the  [tubing size chart](<https://yuannaitube.com/tubing-size-chart/>) .

- Temperature range and media: the technical data sheet on the  [data sheet download page](<https://yuannaitube.com/product-data-sheets/>) .

- How ID, OD and **wall thickness** relate:  [tubing ID, OD and wall thickness](<https://yuannaitube.com/tubing-id-od-wall-thickness/>) .

- How pressure and temperature combine:  [working pressure and temperature](<https://yuannaitube.com/working-pressure-temperature-review/>) .

- Static control or several channels in one piece:  [antistatic PU tubing](<https://yuannaitube.com/products/antistatic-pu-tubing/>)  and  [multi-lumen tubing](<https://yuannaitube.com/products/multi-lumen-tubing/>)  are made to order, so write the resistance range and test method, or the number and size of channels, into the specification.

- Comparing quotations once the specification is written:  [how to choose a tubing supplier](<https://yuannaitube.com/how-to-choose-a-tubing-supplier/>) .

## Frequently Asked Questions: Writing a Tubing Specification

Is tubing specified by ID or OD?

Both, written as ID × OD. Push-in pneumatic fittings match the OD, so OD is the fit dimension; the ID sets flow. Model tables list both for every row.

Do I need the model code if I already give the size?

Yes. A size can exist in several materials with different pressure and bend values, as the 6.0 × 8.0 mm table above shows. The model code fixes the material and the ratings.

What tolerance should I write?

Write the tolerance shown in the model row of the table for your model, with its unit. Each row states it, so the specification and the data match.

Should I specify Shore hardness?

Only if your fitting or application calls for it. Shore A is read on a 0–100 scale under ASTM D2240, and readings on different Shore scales cannot be converted into each other. Hardness alone does not set how flexible a tube is, because **wall thickness** and construction also matter, so give the **bend radius** too. Fitting grip is best checked against the fitting maker’s tubing and fitting compatibility chart; for example, the  [Parker Series U catalog](<https://files.valinonline.com/userfiles/documents/parker-series-u-polyurethane-tube.pdf>)  lists 90–95 Shore A for its polyurethane tube and refers to such a chart.

Which documents can I request with the specification?

The technical data sheet for the family, and the **certificates** and reports published on the  [certificates page](<https://yuannaitube.com/certificates/>) . Name them in the specification so they ship with the order.

**Next step.** Fill the template with your line conditions and send it through the  [contact form](<https://yuannaitube.com/contact/>) ; the  [inquiry checklist](<https://yuannaitube.com/product-data-sheets/#inquiry-checklist>)  covers the remaining details. For non-standard sizes or colors, see  [OEM and custom tubing](<https://yuannaitube.com/oem-custom-tubing/>) .

**Related guides:**  [pneumatic tubing guide](<https://yuannaitube.com/pneumatic-tubing-guide/>)  ·  [push-in fittings and tubing](<https://yuannaitube.com/push-in-fittings-tubing-match/>)  ·  [MOQ, lead time and samples](<https://yuannaitube.com/tubing-moq-lead-time-samples/>)  ·  [what affects tubing price](<https://yuannaitube.com/tubing-price-factors-quote-request/>) .

## Sources and scope

- [PA6 Nylon Tubing — English data sheet (v4-20261020)](<https://yuannaitube.com/wp-content/uploads/2026/10/yuannai-tube-pa6-nylon-technical-data-sheet-en-v4-20261020.pdf>)

- [PA12 Nylon Tubing — English data sheet (v5-20261020)](<https://yuannaitube.com/wp-content/uploads/2026/10/yuannai-tube-pa12-nylon-technical-data-sheet-en-v5-20261020.pdf>)

- [Polyether Tubing — English data sheet (v2-20261020)](<https://yuannaitube.com/wp-content/uploads/2026/10/yuannai-tube-polyether-tpu-technical-data-sheet-en-v2-20261020.pdf>)

- [FEP Tubing — English data sheet (v6-20261020)](<https://yuannaitube.com/wp-content/uploads/2026/10/yuannai-tube-fep-technical-data-sheet-en-v6-20261020.pdf>)

Use these documents for the identified product models and stated test conditions. General material comparisons and selection checklists do not establish a different grade’s rating, fitting compatibility or project approval. Confirm the exact model, medium, temperature, pressure and required evidence before ordering.

Content review:  [zhangkexin](<https://www.linkedin.com/in/%E5%8F%AF%E6%AC%A3-%E5%BC%A0-14b6a7448/>)  · Marketing

Review scope: market information and document references.

## Tell us what your application needs.

Send your dimensions, operating conditions and quantity. Let’s identify the right tubing for your project.

 [Request a Quote →](<https://yuannaitube.com/contact/>)

## Related tubing products

![FEP Tubing](<https://yuannaitube.com/wp-content/uploads/2026/10/company-product-35-1-20261012-768x768.webp>)

[FEP](<https://yuannaitube.com/material/fep/>)

### FEP Tubing

FEP fluoropolymer tubing for strong acid, alkali and solvent lines. 14 models from 2.5 x 4 mm to 12 x 16 mm and 1/8″ to 1/2″, in 100 m rolls. Send your medium for review.

 [View details →](<https://yuannaitube.com/products/fep-tubing/>)

![PA12 Nylon Tubing](<https://yuannaitube.com/wp-content/uploads/2026/10/company-product-34-1-20261012-768x768.webp>)

[PA12](<https://yuannaitube.com/material/pa12/>)

### PA12 Nylon Tubing

PA12 nylon tubing for pneumatic, hydraulic-oil and fuel lines. 14 models from 2.5 x 4 mm to 12 x 16 mm and 1/8″ to 1/2″, in 100 m or 200 m rolls.

 [View details →](<https://yuannaitube.com/products/pa12-nylon-tubing/>)

![PA6 Nylon Tubing](<https://yuannaitube.com/wp-content/uploads/2026/10/product-429-gallery-v1-768-q88-63e58ce6c1.webp>)

[PA6](<https://yuannaitube.com/material/pa6/>)

### PA6 Nylon Tubing

PA6 nylon tubing for fixed pneumatic, oil and fuel lines. 14 models from 2.5 x 4 mm to 12 x 16 mm and 1/8″ to 1/2″, in 100 m or 200 m rolls.

 [View details →](<https://yuannaitube.com/products/pa6-nylon-tubing/>)

![Polyether Tubing](<https://yuannaitube.com/wp-content/uploads/2026/10/product-426-gallery-v1-768-q88-202b509a85.webp>)

[Polyether PU](<https://yuannaitube.com/material/polyether-pu/>)

### Polyether Tubing

Polyether (ether-based) polyurethane tubing for air, water and cleaning-liquid lines. 14 models from 2.5 x 4 mm to 12 x 16 mm and 1/8″ to 1/2″, in 100 m or 200 m rolls.

 [View details →](<https://yuannaitube.com/products/polyether-tubing/>)